Improving the accuracy of a fluid transport method

Authors
Publication date 2013
Journal International Endodontic Journal
Volume | Issue number 46 | 4
Pages (from-to) 348-354
Organisations
  • Faculty of Dentistry (ACTA)
Abstract
Aim
To compare the sealing ability of the same root fillings when measured by a conventional fluid transport method that uses water or by a modified fluid transport method that uses a wetting fluid as tracer.

Methodology
The amount of fluid transport along the same root fillings (AH26, cold lateral compaction of gutta-percha) was measured in a cross-over design in fluid transport set-ups using either water or a wetting fluid as tracer.

Results
A Wilcoxon signed-rank test revealed a significant difference in the amount of fluid transport measured along the same root fillings by the two fluid transport methods (P = 0.013). The fluid transport method using wetting fluid detected a significantly higher percentage of root fillings with fluid transport (P = 0.021).

Conclusions
Fluid transport using a wetting fluid as a tracer was more sensitive in the assessment of sealing ability of root fillings than the conventional fluid transport method using water.
Document type Article
Language English
Published at
Permalink to this page