Radiation hardness of dsipm sensors in a proton therapy radiation environment

Authors
  • F. Diblen
  • T. Buitenhuis
  • T. Solf
  • P. Rodrigues
  • E. van der Graaf
  • M.-J. van Goethem
  • S. Brandenburg
  • P. Dendooven
Publication date 07-2017
Journal IEEE Transactions on Nuclear Science
Volume | Issue number 64 | 7
Pages (from-to) 1891-1896
Number of pages 6
Organisations
  • Faculty of Science (FNWI) - Institute of Physics (IoP)
  • Faculty of Science (FNWI) - Institute of Physics (IoP) - Institute for Theoretical Physics Amsterdam (ITFA)
Abstract

In vivo verification of dose delivery in proton therapy by means of positron emission tomography (PET) or prompt gamma imaging is mostly based on fast scintillation detectors. The digital silicon photomultiplier (dSiPM) allows excellent scintillation detector timing properties and is thus being considered for such verification methods. We present here the results of the first investigation of radiation damage to dSiPM sensors in a proton therapy radiation environment. Radiation hardness experiments were performed at the AGOR cyclotron facility at the KVI-Center for Advanced Radiation Technology, University of Groningen. A 150-MeV proton beam was fully stopped in a water target. In the first experiment, bare dSiPM sensors were placed at 25 cm from the Bragg peak, perpendicular to the beam direction, a geometry typical for an in situ implementation of a PET or prompt gamma imaging device. In the second experiment, dSiPM-based PET detectors containing lutetium yttrium orthosilicate scintillator crystal arrays were placed at 2 and 4 m from the Bragg peak, perpendicular to the beam direction; resembling an in-room PET implementation. Furthermore, the experimental setup was simulated with a Geant4-based Monte Carlo code in order to determine the angular and energy distributions of the neutrons and to determine the 1-MeV equivalent neutron fluences delivered to the dSiPM sensors. A noticeable increase in dark count rate (DCR) after an irradiation with about 108 1-MeV equivalent neutrons/cm2 agrees with observations by others for analog SiPMs, indicating that the radiation damage occurs in the single photon avalanche diodes and not in the electronics integrated on the sensor chip. It was found that in the in situ location, the DCR becomes too large for successful operation after the equivalent of a few weeks of use in a proton therapy treatment room (about 5× 103 protons). For PET detectors in an in-room setup, detector performance was unchanged even after an irradiation equivalent to three years of use in a treatment room (3× 1015 protons).

Document type Article
Language English
Published at
https://doi.org/10.1109/TNS.2017.2705522 (Final published version)
Other links
Permalink to this page
Back