The UvA-LINKER will give you a range of other options to find the full text of a publication (including a direct link to the full-text if it is located on another database on the internet).
De UvA-LINKER biedt mogelijkheden om een publicatie elders te vinden (inclusief een directe link naar de publicatie online als deze beschikbaar is in een database op het internet).

Zoekresultaten

Zoekopdracht: faculteit: "ACTA" en publicatiejaar: "2010"

AuteursA. Tahmaseb, J.J. van der Weijden, P. Mercelis, R. De Clerck, D. Wismeijer
TitelParameters of passive fit using a new technique to mill implant-supported superstructures: an in vitro study of a novel three-dimensional force measurement-misfit method
TijdschriftInternational Journal of Oral & Maxillofacial Implants
Jaargang25
Jaar2010
Nummer2
Pagina's247-257
ISSN08822786
FaculteitACTA
SamenvattingPurpose: The objectives of this study are to describe, in vitro, a novel technique to measure the misfit of digitally designed and manufactured implant-supported frameworks according to a new concept based on computer-guided surgery in combination with previously placed mini-implants. Also, the digitally created framework and an impression-based milled structure were compared using strain gauge measurements. Materials and Methods: Acrylic resin and plaster models were prepared to represent the edentulous mandible. After insertion of three mini-implants in the acrylic resin model, a cone-beam computed tomographic scan was performed. The data were imported to planning software, where six implants were virtually inserted. A drill guide and titanium framework were designed and milled using a fully digital computer-aided design/computer-assisted machining protocol. Six implants were inserted using the drill guide attached to the mini-implants. After an impression was made of the acrylic resin model with six implants, the second model (plaster model) was prepared. A second milled titanium structure was fabricated following optical scanning of the acrylic resin model. Strain gauge measurements were done on both structures attached to both models. To validate the results, a high-accuracy industrial optical scanning system was used to capture all connection geometry and the measurements were compared. Results: The accuracy of the digital superstructures was 19, 22, and 10 µm with standard deviations (SD) of 19.2 (17.9), 21.5 (28.3), and 10.3 (10.1) µm for the x-, y-, and z-axes, respectively. For the impression-based superstructure the measured misfit was 11, 20, and 17 µm, with SD 11.8 (10.5), 19.7 (11.7), and 16.7 (8.2) µm for the x-, y-, and z-axes, respectively. Conclusion: The misfit of the digitally designed and produced superstructure on the digitally planned and inserted implants was clinically insignificant.
Soort documentArtikel
Document finderUvA-Linker