Zoekopdracht:
faculteit: "FNWI" en publicatiejaar: "2010"
| Auteurs | J.A. Aguilar, . et al., P. Kooijman, G. Lim, D. Palioselitis, E. Presani, G. Wijnker, E. de Wolf | | Titel | Performance of the front-end electronics of the ANTARES neutrino telescope |
| Tijdschrift | Nuclear Instruments & Methods in Physics Research Section A - Accelerators Spectrometers Detectors and Associated Equipment |
| Jaargang | 622 |
| Jaar | 2010 |
| Nummer | 1 |
| Pagina's | 59-73 |
| ISSN | 01689002 |
| Faculteit | Faculteit der Natuurwetenschappen, Wiskunde en Informatica |
| Instituut/afd. | FNWI: Institute for High Energy Physics (IHEF) |
| Samenvatting | ANTARES is a high-energy neutrino telescope installed in the Mediterranean Sea at a depth of 2475 m. It consists of a three-dimensional array of optical modules, each containing a large photomultiplier tube. A total of 2700 front-end ASICs named analogue ring samplers (ARS) process the phototube signals, measure their arrival time, amplitude and shape as well as perform monitoring and calibration tasks. The ARS chip processes the analogue signals from the optical modules and converts information into digital data. All the information is transmitted to shore through further multiplexing electronics and an optical link. This paper describes the performance of the ARS chip; results from the functionality and characterization tests in the laboratory are summarized and the long-term performance in the apparatus is illustrated. |
| Soort document | Artikel |
| Document finder |
|
Gebruik dit adres om naar deze pagina te linken: http://dare.uva.nl/record/370547
Vraag/opmerking over dit recordMail aan een collega
Toevoegen aan bewaarset
|